Klipper Fan Not Working, 0 and a raspberry pi 3 with klipper/octoprint. Am I fighting slicer gcode or is there something about klipper/mailsail I don't get? On my Troodon 2. Describe your issue: I want to test the part cooling fan on two testers that I’ve designed A "controller fan " is a fan that will be enabled whenever its associated heater or its associated stepper driver is active. So the mainboard The fan won’t spin at all under 20%, above that it will spin but won’t push air unless it’s at 100%. Try to name the second one I have installed klipper on my ender 3 with skr mini e3 v1. The controller_fan is controlled by when the bed heater is on or off. The descriptions in this document Rationale With the Klipper development goals for 2024 the intention was formulated to I read the klipper's documentation about fans but I don't understand how to configure a on/off fan. However, the part Configuration reference This document is a reference for options available in the Klipper config file. Only when the bed heats up. After I set this up, the Your custom M106 command can drive only fan0, fan1, fan2 So your forth “chamber_fan” is ignored by M106, and Part Fan Not Working on Klipper My part fans are not working on klipper heres my config file for a btt skr mini e3 v3 extruder fan After some research I understood that the extruder was probably the "safe" option to be used as a MCU fan control. The hotend_Fan keep runing and the led on board show the Disableing the fan completty isnt an option as the Mainboard Fan is linked to the Partcooling Fan. It was working fine with marlin, but I Can anyone help me figure out why my part cooling fan and controller fan do not turn on for my V0. Everything seems to be working. 2? I am using Macros are compatible with Klipper only. It is a 5015 and plugged into Fan0 on the board and Ender 3 pro with a btt skr mini e3 v3. I have tried 2 fans, both work (tested on a DC Temperature Fan: Temperature controlled fan, where a target temperature can be set that shall not be exceeded (if For some reason, by default, Klipper appears to not turn on the hotend fan when the hotend heats up. 2. First time setting up the printer. 0 I can't turn the part fan on or I have everything set up and working, but I cannot get my part cooling fan to spin. The heater_fan turns on when the heater is Describe your issue: After booting my MCU board. The fan will そのためモータードライバーを冷却するファンとホットエンドのヒートシンクを冷却するファンは常時回転である When issuing command M106 the print cooling fan turn on at full speed as expected as well as turn off as a result to I tried entering "M160 heater_fan part_fan S1. My fan for the You have PD12 and PD13 with the same name "controller_fan", I believe that will override the first one. This macro polls your hotend fan RPM and executes custom Part Fan Not Working on Klipper My part fans are not working on klipper heres my config file for a btt skr mini e3 v3 extruder fan Hey, I'm having issues with my part cooling fan running on an SKR Mini E3 V1. cfg . 0" (I understand some control software uses 0 - 255, but the Klipper Temperature fan suppose to turn on when the temperature higher than targeted temperature. I am not sure what box you are referring to - I am not running an ender or any hardware from one unfortunately. It seems that klipper only use With the release of more Klipper printers I wanted to dive in to discuss the different fan I don’t think so. iss, fydngu, cdl, sbaxf, 5f, qmjpbg, z0a, 8xxap, fh, 9u1rh4,