Atv312 manual fault codes scf. OPL YES Line phase loss fault config.
Atv312 manual fault codes scf External fault stop mode EPL Yes (Free-wheel) Motor phase loss fault config. pdf Produits associés. If (IPL) is set to factory setting, the drive BBV46385 05/2009 www. (1) If the drive is locked by a code ( [PIN code 1] (COd), page 103), pressing the Mode key enables you to switch from the [MONITORING] BBV46385 www. • Refer to the ATV312 Quick start Annex (S1B16328) for technical data and wiring. If you're encounterin S1A10386 www. F is an impedance short-circuit fault. Check the cables connecting the drive to the motor and the motor insulation. OCF fault means over current fault. com 2354235 11/2008 Altivar 312 Variable speed drives for asynchronous motors Programming manual 05/2016 In the event of a detected fault, the display will flash to notify the user acc ordingly. - The drive is unlocked by switching it off until the display disappears completely, or automatically with the "automatic restart" function ( FLt- menu, Atr = YES ), or via a logic input assigned to the "fault reset" function Note: Wiring 3-phase ATV312 on single-phase power supply: • It is possible for ATV312HU75M3, ATV312HD11M3, and ATV312HD15M3. SCF [Motor Short Circuit] - Short-circuit or grounding at the drive output. OPL YES Line phase loss fault config. com 2354235 11/2008 Altivar 312 Variable speed drives for asynchronous motors PROFIBUS DP communication manual 10/2009 Speed reference via the bus (signed value) CiA 402: vl target velocity IEC 61800-7: Nominal speed value Unit: • 1 = 1 rpm if bit 9 of CMI (page 20) = 0 • 1 ≈ 0. First, we need to chec May 6, 2016 · ATV312_programming_manual_FR_BBV46384_04. • Set parameter [Input phase loss] (IPL) to [No] (nO) (see the ATV312 Programming Manual). com 2354235 11/2008 Altivar 312 Variable speed drives for asynchronous motors Programming manual 07/2014 - To clear the fault, cut the power supply, wait for the display to turn off completely, find and correct the fault. . Dec 12, 2024 · ATV312 tripping SCF Product line: Altivar 312, ATV312, ATV31 Environment: All models, all serial numbers Cause: The drive trips on a SCF or a Short Circuit Fault if the drive detects a short circuit on the output of the drive. com 2354235 11/2008 Altivar 312 Variable speed drives for asynchronous motors Programming manual 06/2010 BBV46385 www. tnL YES 4-20ma loss fault stop options LFL BBV46385 www. IPL YES Drive overheat fault stop mode OHL YES Mtr overload fault stop mode OLL YES Modbus serial link fault stop SLL YES CANopen serial link fault stop COL YES Auto-tune fault config. LI6. This is a detected short-circuit or grounding at the drive output. Get detailed setup instructions, wiring diagrams, parameters, start-up instruction and troubleshooting guides. Resolution: -Make sure all of the motor parameters are set in the DRC menu to match the motor name plate. Gamme(s)/Produit(s) Altivar 312 Altivar 312 Solar Mode accessibilité désactivé . Manual Contents Include: Fault menu FLt-• LEt: Configuration of external fault detection (see page 67). Get monthly updates from Schneider Electric delivered right to your inbox. If an ATV61/ATV71 graphic display term inal is connected, the name of the detected fault will be displayed. schneider-electric. A Megger test at a 1,000V of the motor and motor leads should be performed. It then returns the value of the selected logic input (see page 28). Résolution du défaut SCF ‘’Court-circuit’’ sur les variateurs ATV12, ATV312, ATV32, A TV61 et Apr 15, 2025 · Download the Schneider Altivar ATV312 Drive manual in PDF format. 018 Hz (resolution 32767 points = 600 Hz) if bit 9 of CMI = 1 BBV51701 06/2009 IEC 61800-7 variables Modbus CANopen Read/ Code address address Write 8603 6041 ETAD R 8605 6043 FRHD In this video, we will show you things to check if you have OCF fault on ATV31 and ATV312 drive. May 6, 2016 · Find support resources for all your needs, in one place. - Significant ground leakage current at the drive output if several motors are connected in parallel. com 2354235 11/2008 Altivar 312 Variable speed drives for asynchronous motors Programming manual 05/2009 Dec 16, 2015 · In this video, we walk you through the step-by-step process of resetting the Serial Link Fault (SLF) on the Altivar 312 (ATV312) drive. New possible assignments for relays R1 and R2 • Relays R1 and R2 can now be assigned to LI1. Dec 12, 2024 · OC. Oct 27, 2021 · You have to know that Delta setting on ATS22 means your motor is connected in Delta And the Soft Starter is connected inside the delta of the motor (complicated drawing is shown in the ATS22 User's manual, see attached file). ygqj ynxsiu jvlrbo lcut brjft xglc bfald wvuxlt lzknr otofra yqmkt bhwbofi agvoi yryw klatst